Home & ConstructionCanada versionFormula-based · Runs in your browser

Heating Cost Comparison Calculator — Canada

Put electricity and the comparison fuel on the same delivered-heat basis instead of comparing unlike fuel units. CAD planning view; stated limitations apply.

Preparing saved example…

Inputs

Enter the values you know. Optional fields may be left empty.

Local save controls below
Required
Required
Required
%
Required
CAD
Required
CAD
Required
CAD
Required
CAD

Result

Updates as valid inputs change.

Calculated locally
Illustrative defaults are not local quotes or verified legal rules. Dated reference components and user-entered assumptions are explicitly distinguished. Professional review is pending.
Heat-pump annual saving
—
Heat-pump input electricity, kWh
—
Comparison fuel input, kWh
—
Heat-pump annual cost
—
Comparison heater annual cost
—
Energy-only break-even COP
—

Saved locally, explained clearly

Drafts, calculations, scenarios, and workflow progress stay in this browser unless you export them.

Opening local database…

Calculation steps

Follow what happened from the selected formula to the displayed answer.

Show substituted values and intermediate working
Calculate current inputs to see the working.
  1. 1

    Formula selected

    The calculator uses the following formula or method.

    input energy = useful heat ÷ seasonal efficiency; cost = input energy × unit price + fixed charges.

    Inputs are converted to canonical units before evaluating this stated formula.

  2. 2

    Values entered

    Your values are placed into the calculation.

    Enter values to see what is used in this step.

  3. 3

    Result calculated

    The formula or method produces the following result values.

    Results will appear after a successful calculation.

  4. 4

    Answer formatted

    Displayed values are rounded and formatted using each output’s configured precision.

Scenario comparison

Save working scenarios, then select two or three to compare. Formula versions and inputs remain visible.

No scenarios saved for this calculator yet.

Recent calculations

Successful calculations are retained locally according to your privacy settings.

No local history for this calculator yet.

Data and privacy

How it works

Put electricity and the comparison fuel on the same delivered-heat basis instead of comparing unlike fuel units.

This is the Canada planning view, with monetary inputs and outputs in CAD. A currency label does not establish that a tax rate, construction price, coverage rule or legal limit has been verified locally. The inputs and limitations below describe the actual scope.

Input query strings and outputs

Use an input name in this page’s URL as ?name=value, and join additional inputs with &. Portable shared links may instead use the compact ?ac= state parameter.

Input query strings

7
  • ?usefulHeat= Annual useful heat required, kWh

    Number · Required · Default: 18,000

  • ?heatPumpCop= Seasonal heat-pump coefficient of performance

    Number · Required · Default: 3

  • ?fuelEfficiency= Seasonal comparison-heater efficiency

    Percentage · Required · Default: 90

  • ?electricityRate= Electricity price per input kWh

    Money · Required · Default: 0.2

  • ?fuelRate= Comparison fuel price per input kWh

    Money · Required · Default: 0.08

  • ?electricFixed= Annual additional electric fixed charges

    Money · Required · Default: 0

  • ?fuelFixed= Annual fuel fixed charges

    Money · Required · Default: 120

Outputs

6
  • heatPumpEnergy Heat-pump input electricity, kWh

    Number

  • fuelEnergy Comparison fuel input, kWh

    Number

  • heatPumpCost Heat-pump annual cost

    Currency · Currency: CAD

  • fuelCost Comparison heater annual cost

    Currency · Currency: CAD

  • annualSaving Heat-pump annual saving

    Currency · Primary output · Currency: CAD

  • breakevenCop Energy-only break-even COP

    Number

Formula

input energy = useful heat ÷ seasonal efficiency; cost = input energy × unit price + fixed charges.

Calculations retain numeric precision internally. Displayed values are rounded for readability. Quantities that must be purchased as whole units are rounded up only where the formula explicitly requires it.

Read the inputs before calculating

  • Annual useful heat required, kWh: Enter the quantity described by the label.
  • Seasonal heat-pump coefficient of performance: Enter the quantity described by the label.
  • Seasonal comparison-heater efficiency: Enter the quantity described by the label.
  • Electricity price per input kWh: Enter the quantity described by the label.
  • Comparison fuel price per input kWh: Enter the quantity described by the label.
  • Annual additional electric fixed charges: Enter the quantity described by the label.
  • Annual fuel fixed charges: Enter the quantity described by the label.

Reproducible worked example

The following is a fictional arithmetic example, not a local quote, a verified claimant or a market forecast. Its values are included so the formula can be checked. The form does not automatically confirm any verification checkbox.

InputExample value
Annual useful heat required, kWh18,000
Seasonal heat-pump coefficient of performance3
Seasonal comparison-heater efficiency90
Electricity price per input kWh0.2
Comparison fuel price per input kWh0.08
Annual additional electric fixed charges0
Annual fuel fixed charges120
OutputCalculated result
Heat-pump input electricity, kWh6,000
Comparison fuel input, kWh20,000
Heat-pump annual costCAD 1,200
Comparison heater annual costCAD 1,720
Heat-pump annual savingCAD 520
Energy-only break-even COP2.25

Interpreting a changed assumption

Start with one complete scenario and change only one input when diagnosing a difference. Recheck units, the period of every rate, whether an amount is recurring or one-off, and whether a cost is already included elsewhere. A larger calculated benefit is not evidence that an assumption is more likely to occur.

Limitations

  • Fuel must be priced per input kWh, not per gallon, therm, litre or cubic metre without a verified conversion. Seasonal COP is not a single mild-weather test value.

Frequently asked questions

What does this Heating Cost Comparison result represent?

Put electricity and the comparison fuel on the same delivered-heat basis instead of comparing unlike fuel units. It applies the displayed formula to your inputs; it does not infer omitted facts.

No. Numeric defaults are illustrative unless an input or dated reference explicitly identifies a researched component. Currency is CAD; local quotes, eligibility and unsupported rules must be entered and verified separately.

What must I check before relying on the result?

Check the input units, supplier or authority evidence, the stated model exclusions and the period used for costs. This arithmetic does not supply missing site-specific design or local legal rules.

Can I compare or share different assumptions?

Change one assumption at a time and use the browser-local project or share controls. A shared URL contains the encoded input values; do not include information you do not wish to disclose.

Sources and reference scope

  • DOE energy-use arithmetic — retrieved 2026-09-24. Energy consumption versus power; not a local tariff or an approval of this implementation.
  • PVWatts: site-specific solar estimation — retrieved 2026-09-24. External site-yield model. AskCalculators uses your entered yield; it does not call or reproduce PVWatts.
  • DOE insulation overview — retrieved 2026-09-24. Insulation and thermal resistance concepts; not structural or code approval.

These references support only their stated scope. They are not evidence that every local rule or price needed by the master expansion has been loaded.

Sources
Limitations
  • Illustrative defaults are not local quotes or verified legal rules. Dated reference components and user-entered assumptions are explicitly distinguished. Professional review is pending.
  • Inputs are converted to canonical units before evaluating this stated formula.
  • Material quantities are estimates. Confirm site dimensions, product coverage, waste, and local requirements before ordering or construction.
A LITTLE MORE LOCAL

Where are you calculating?

Choose your country for local calculator versions. You can change it anytime in the navigation bar.

Choose a country