Relate a specified mixed-water draw to ideal storage and recovery power using an explicit temperature balance. EUR planning view; stated limitations apply.

Preparing saved example…

Inputs

Enter the values you know. Optional fields may be left empty.

Local save controls below
Optional
Required
L
Required
°C
Required
°C
Required
°C
Required
Required
%
Required
EUR
Required
EUR
Required
EUR
Required
EUR
Required
Required
%
Required
%

Result

Updates as valid inputs change.

Calculated locally
Illustrative defaults are not local quotes or verified legal rules. Dated reference components and user-entered assumptions are explicitly distinguished. Professional review is pending.
Middle cost scenario
—
Ideal usable hot-water storage
—
Useful recovery heat, kWh
—
Required input power, kW
—
Material cost
—
Labor allowance
—
Delivery allowance
—
Other specified costs
—
Entered tax allowance
—
Low cost scenario
—
High cost scenario
—

Saved locally, explained clearly

Drafts, calculations, scenarios, and workflow progress stay in this browser unless you export them.

Opening local database…

Calculation steps

Follow what happened from the selected formula to the displayed answer.

Show substituted values and intermediate working
Calculate current inputs to see the working.
  1. 1

    Formula selected

    The calculator uses the following formula or method.

    ideal stored volume = mixed draw × (delivery − cold) ÷ (storage − cold); useful kWh = mixed litres × 4.186 × (delivery − cold)/3,600.

    Inputs are converted to canonical units before evaluating this stated formula.

  2. 2

    Values entered

    Your values are placed into the calculation.

    Enter values to see what is used in this step.

  3. 3

    Result calculated

    The formula or method produces the following result values.

    Results will appear after a successful calculation.

  4. 4

    Answer formatted

    Displayed values are rounded and formatted using each output’s configured precision.

Scenario comparison

Save working scenarios, then select two or three to compare. Formula versions and inputs remain visible.

No scenarios saved for this calculator yet.

Recent calculations

Successful calculations are retained locally according to your privacy settings.

No local history for this calculator yet.

Data and privacy

How it works

Relate a specified mixed-water draw to ideal storage and recovery power using an explicit temperature balance.

This is the Ireland planning view, with monetary inputs and outputs in EUR. A currency label does not establish that a tax rate, construction price, coverage rule or legal limit has been verified locally. The inputs and limitations below describe the actual scope.

Input query strings and outputs

Use an input name in this page’s URL as ?name=value, and join additional inputs with &. Portable shared links may instead use the compact ?ac= state parameter.

Input query strings

14
  • ?unitSystem= Measurement system

    Choice · Optional · Default: metric · Accepted values: imperial, metric

  • ?peakLitres= Mixed hot-water draw in the design period

    Number · Required · Default: 150

  • ?coldTemp= Cold inlet temperature

    Number · Required · Default: 10

  • ?deliveryTemp= Required mixed delivery temperature

    Number · Required · Default: 40

  • ?storageTemp= Specified storage temperature

    Number · Required · Default: 60

  • ?recoveryHours= Allowed recovery period, hours

    Number · Required · Default: 2

  • ?efficiency= Recovery input-to-water efficiency

    Percentage · Required · Default: 90

  • ?unitRate= Material price per quoted water-heater project

    Money · Required · Default: 0

  • ?laborCost= Total labor allowance

    Money · Required · Default: 0

  • ?deliveryCost= Delivery allowance

    Money · Required · Default: 0

  • ?otherCost= Other fixed costs

    Money · Required · Default: 0

  • ?costMultiplier= Material/labor multiplier

    Number · Required · Default: 1

  • ?spreadPercent= Low/high sensitivity around the entered total

    Percentage · Required · Default: 15

  • ?taxRate= Explicit tax allowance

    Percentage · Required · Default: 0

Outputs

11
  • storedLitres Ideal usable hot-water storage

    Number

  • usefulKwh Useful recovery heat, kWh

    Number

  • inputKw Required input power, kW

    Number

  • materialCost Material cost

    Currency · Currency: EUR

  • laborCost Labor allowance

    Currency · Currency: EUR

  • deliveryCost Delivery allowance

    Currency · Currency: EUR

  • otherCost Other specified costs

    Currency · Currency: EUR

  • tax Entered tax allowance

    Currency · Currency: EUR

  • low Low cost scenario

    Currency · Currency: EUR

  • mid Middle cost scenario

    Currency · Primary output · Currency: EUR

  • high High cost scenario

    Currency · Currency: EUR

Formula

ideal stored volume = mixed draw × (delivery − cold) ÷ (storage − cold); useful kWh = mixed litres × 4.186 × (delivery − cold)/3,600.

Calculations retain numeric precision internally. Displayed values are rounded for readability. Quantities that must be purchased as whole units are rounded up only where the formula explicitly requires it.

Read the inputs before calculating

  • Mixed hot-water draw in the design period: Enter the quantity described by the label. The measurement selector converts this physical quantity; it does not change the underlying scenario.
  • Cold inlet temperature: Enter the quantity described by the label. The measurement selector converts this physical quantity; it does not change the underlying scenario.
  • Required mixed delivery temperature: Enter the quantity described by the label. The measurement selector converts this physical quantity; it does not change the underlying scenario.
  • Specified storage temperature: Enter the quantity described by the label. The measurement selector converts this physical quantity; it does not change the underlying scenario.
  • Allowed recovery period, hours: Enter the quantity described by the label.
  • Recovery input-to-water efficiency: Enter the quantity described by the label.
  • Material price per quoted water-heater project: Zero means unpriced, not free. Enter a current, scoped supplier quote.
  • Total labor allowance: Enter the quantity described by the label.
  • Delivery allowance: Enter the quantity described by the label.
  • Other fixed costs: Enter the quantity described by the label.
  • Material/labor multiplier: Use a verified regional index only when supplied. 1 is an unadjusted scenario, not a researched index.
  • Low/high sensitivity around the entered total: Enter the quantity described by the label.
  • Explicit tax allowance: Enter the quantity described by the label.

Reproducible worked example

The following is a fictional arithmetic example, not a local quote, a verified claimant or a market forecast. Its values are included so the formula can be checked. The form does not automatically confirm any verification checkbox.

InputExample value
Mixed hot-water draw in the design period (L)150
Cold inlet temperature (°C)10
Required mixed delivery temperature (°C)40
Specified storage temperature (°C)60
Allowed recovery period, hours2
Recovery input-to-water efficiency90
Material price per quoted water-heater project0
Total labor allowance0
Delivery allowance0
Other fixed costs0
Material/labor multiplier1
Low/high sensitivity around the entered total15
Explicit tax allowance0
OutputCalculated result
Ideal usable hot-water storage90 L
Useful recovery heat, kWh5.2325
Required input power, kW2.9069
Material costEUR 0
Labor allowanceEUR 0
Delivery allowanceEUR 0
Other specified costsEUR 0
Entered tax allowanceEUR 0
Low cost scenarioEUR 0
Middle cost scenarioEUR 0
High cost scenarioEUR 0

Interpreting a changed assumption

Start with one complete scenario and change only one input when diagnosing a difference. Recheck units, the period of every rate, whether an amount is recurring or one-off, and whether a cost is already included elsewhere. A larger calculated benefit is not evidence that an assumption is more likely to occur.

Limitations

  • Quantities and user-entered costs are planning estimates. Drawings, manufacturer instructions, local permits and qualified site-specific design take precedence.
  • Material is unpriced. A zero material price is not evidence that the material is free.
  • Prices and the tax allowance are user-entered planning assumptions, not a verified local quote. Low/high outputs are sensitivity scenarios, not market confidence limits.
  • The multiplier applies only to material and labor; delivery and fixed costs are not multiplied.
  • Ideal mixing excludes standby losses, draw stratification, first-hour rating and distribution losses. Temperatures are inputs, not advice: a qualified installer must address scalding, microbial controls and local requirements.

Frequently asked questions

What does this Water Heater Storage and Recovery result represent?

Relate a specified mixed-water draw to ideal storage and recovery power using an explicit temperature balance. It applies the displayed formula to your inputs; it does not infer omitted facts.

No. Numeric defaults are illustrative unless an input or dated reference explicitly identifies a researched component. Currency is EUR; local quotes, eligibility and unsupported rules must be entered and verified separately.

What must I check before relying on the result?

Quantities and user-entered costs are planning estimates. Drawings, manufacturer instructions, local permits and qualified site-specific design take precedence.

Can I compare or share different assumptions?

Change one assumption at a time and use the browser-local project or share controls. A shared URL contains the encoded input values; do not include information you do not wish to disclose.

Sources and reference scope

  • NIST unit conversion guidance — retrieved 2026-09-24. Unit definitions; geometry and financial arithmetic in these worksheets are explicitly stated.
  • DOE insulation overview — retrieved 2026-09-24. Insulation and thermal resistance concepts; not structural or code approval.

These references support only their stated scope. They are not evidence that every local rule or price needed by the master expansion has been loaded.

Sources
Limitations
  • Illustrative defaults are not local quotes or verified legal rules. Dated reference components and user-entered assumptions are explicitly distinguished. Professional review is pending.
  • Inputs are converted to canonical units before evaluating this stated formula.
  • Material quantities are estimates. Confirm site dimensions, product coverage, waste, and local requirements before ordering or construction.
A LITTLE MORE LOCAL

Where are you calculating?

Choose your country for local calculator versions. You can change it anytime in the navigation bar.

Choose a country